3 things you need to know about the new OSHA standard changes
- Electric utilities (some larger industrial
workers) and their contractors are required to wear flame resistant clothing for arc flash
exposures effective July 11, 2014. FR clothing is defined as non-melting, non-ignitable but
does not have to be matched to the hazard until April 1, 2015.
- Arc flash clothing for these workers is now PPE and must be paid for by the employer.
- Arc flash hazard assessment is required for
these companies by January 1, 2015 and PPE, matching the hazard, is required by April 1,
2015.
|
FREE Webinar on OSHA Standard Changes with Hugh Hoagland
|
STANDARD NEWS!
Hugh Hoagland will lead webinar discussing new OSHA standard changes
June 17, 2014
2:00PM ET/1:00PM CT/11:00AM PT
-
Overview of changes to standard 1910.269
-
Practical advice on meeting the new standard
-
Notes will also be offered on the changes in 1910.137
*See more upcoming events below
|
Q&A with e-Hazard/ArcWear:
|
Q.
Can someone tell me if your rubber gloves need to be replaced with
new ones if they are tested every 6 months and pass the test? I was told they are to be replaced
at 1-year intervals whether they pass or not.
A.
As long as the gloves pass the test every 6 months, they are
acceptable for use. I have seen class 0 gloves that have lasted 6-8 years if properly protected
and used with the correct glove talc. I've also seen the "baby powder glove
approach" that won't make three tests. It's all in the usage, proper storage and
correct glove talc or glove liner.
If your folks are using baby powder, the glove will not last very long.– Lee Hale
A. Gloves are replaced when they fail a visual inspection, air test or electrical test. If there is anything that makes a worker suspect the glove is unfit for service, feel free to replace it but there is no annual replacement requirement.
Many high voltage gloves will last for 5-8 years depending on use. Please use ASTM F496 and the manufacturer's website for guidance. – Hugh Hoagland
Got a question?
The only bad question is the one you didn't ask
until after the accident!
|
Greensboro, NC
|
5/2/14
|
Reno, NV – FULL
|
5/6/14
|
Reno, NV
|
5/8/14
|
Lafayette,
IN
|
5/13/14
|
Cleveland,OH
|
6/10/14
|
Jacksonville, FL
|
6/10/14 |
Louisville, KY |
6/16/14
|
Seattle-Lynnwood, WA,
|
7/22/14
|
College Park-Atlanta,
GA
|
7/29/14
|
Slidell, LA
|
8/12/14
|
Henderson-Las Vegas, NV
|
8/19/14
|
|
|
|
|
Training and Testing Needs
|
program is designed to prepare qualified trainers to deliver instruction based on NFPA 70E and OSHA requirements.
"The instructor was very knowledgeable and professional"
6/16 – 6/19/14
9/29 – 10/2/14
12/1 – 12/4/14
|
|
Arc Flash Testing for Protective Apparel
|
Arc Flash Training on Melting or Kevlar Chums
|
Testing Dates 2014
May 12 – 16
June 23 – 27
July 28 – August 1
September 22 – 26
October 14 – 20
ArcWear now provides ISO 17025 A2LA Accredited testing for ASTM F1506 and F1891 along with our other arc flash standards.
|
|
Read our Electrical and Arc Flash Safety BLOG
|
Redefining PPE classifications
|
Changes are coming to the way we refer to PPE classifications in NFPA 70E. The new NFPA 70E 2015 version, due in Aug/Sept 2014, eliminates the commonly used term HRC (Hazard/Risk Category), which described the level of PPE needed for specific tasks in the PPE tables. Instead, the new NFPA 70E will use the term "arc rated PPE category," or simply "PPE level". It should be noted that HRC has never been required on clothing. ASTM F1506 and other arc flash standards like ASTM F1891 (rainwear), ASTM F2178 (eye and face protection) or ASTM F2675 (gloves) do not require HRC levels — they require that the cal/cm 2 garment rating be used.
That being said the HRCs have become very common on clothing and the levels are still there but will be called PPE categories or PPE levels. The categories remain essentially the same; for example, the current HRC 3, encompassing the range of 25 to 39 cal/cm 2, will still be PPE level 3, etc. (see chart).
Arc Rated Category |
Typical Clothing Description
(Typical number of layers is given in parentheses) |
Required Minimum Arc Rating of PPE cal/cm 2 |
|
FR shirt and FR pants or coveralls, Faceshield/Hardhat (1 layer) natural fiber underlayer allowed |
4 |
|
FR shirt an FR pants or coverall (1 or 2 layers) Faceshield/Hardhat w/balaclava |
8 |
|
FR shirt and FR pants or coverall plus FR coveralls, or two FR coveralls (2 or 3 layers) with arc flash hood |
25 |
|
FR shirt and FR pants or coverall plus multilayer flash suit (3 or more layers) with arc flash hood |
40 |
We recommend using something like ARC1, ARC2, etc. to keep something like the HRC and still be clear to the end user if you choose to use these levels on labels.
Read more…
Are you compliant?
|
Visit the e-Hazard online forum
|
Be a part of the conversation.
Have questions on the recently released standard changes (OSHA 1910.269)? Visit the
e-Hazard forum today and ask our electrical safety experts questions about how it applies to you.
Read what other electrical safety professionals around the globe are saying about the latest developments with the OSHA standards and other pertinent electrical safety news.
Electrical safety networking at your fingertips.
Visit our forum
today for online discussions
regarding arc flash and electrical safety.
|
Product Spotlight:
PBI Lightweight Gold 40-Cal (Advertisement)
|
PBI Lightweight Gold 40-cal suit:
The newest, most innovative HRC 4 suit on the market
A hazardous arc flash can occur in any electrical device,
regardless of voltage, in which the energy is high enough
to sustain an arc. This would include panel boards,
switchgear, transformers and any place that could have
equipment failure. For years, the safety industry has been searching for lighter weight protection that would stand up against these real and ever present dangers.
Read more…
|
|
Please help us welcome Sarah Meehan to our team as our new QuickBooks Specialist. Sarah has over eleven years of experience in bookkeeping with both a medium sized family owned business and a larger organization. She is extremely proficient in multiple software programs and we look forward to having her expertise on our team.
Welcome to the e-Hazard/ArcWear family!
|
|
|
|
What a tangled web…
We'd love to have you
join us
on
Facebook.
It's a great way to stay
connected to the latest electrical
safety news through social media and
you can check out our
What
Not To Do
photo series!
Come on and join us!
|
|
Upcoming Events Hugh Hoagland from e-Hazard Speaking
|
Hugh Hoagland has been scheduled to speak at the 2014 National Safety Council (NSC) Congress & Expo in San Diego on September 13 -19,2014. Hoagland will be addressing the recent updates to OSHA 1910.269 and other electrical standards in 2014.
|
May 6-9, 2014
The Galt House Hotel
|
"Electricity and safety in the
21st century"
Hugh Hoagland to speak
August 24-27, 2014
|
|
|